{"id":22823,"date":"2023-10-18T23:36:51","date_gmt":"2023-10-18T22:36:51","guid":{"rendered":"http:\/\/indolighting.com\/?p=22823"},"modified":"2026-07-31T09:18:55","modified_gmt":"2026-07-31T08:18:55","slug":"fotometri-absolut-eller-relativ-2","status":"publish","type":"post","link":"https:\/\/indolighting.com\/da\/fotometri-absolut-eller-relativ-2\/","title":{"rendered":"Fotometri: absolut eller relativ?"},"content":{"rendered":"<h4><span style=\"color: #00a5db;\">Lawrence Baynham og Toby Penter ser n\u00e6rmere p\u00e5 de to m\u00e5der at pr\u00e6sentere vejbelysningsproducenters data p\u00e5.<\/span><\/h4>\n<p><strong>N\u00e5r man designer en vejbelysningsinstallation, er kvaliteten og n\u00f8jagtigheden af de fotometriske data af allerst\u00f8rste betydning. Du er sikkert klar over, at producenters data kan pr\u00e6senteres i to formater: absolut fotometri og relativ fotometri. Men hvilket format b\u00f8r du bruge? Er det ene mere n\u00f8jagtigt end det andet?<\/strong><\/p>\n<p>Det korte svar er nej, de giver begge de samme resultater. Lad os se n\u00e6rmere p\u00e5 de to metoder for at forst\u00e5 hvorfor.<\/p>\n<h4><strong>Relativ fotometri: elementerne forklaret<\/strong><\/h4>\n<p>Relativ fotometri er baseret p\u00e5 at opdele m\u00e5lingen af en lyskilde (eller \u201clampe\u201d) isoleret set og derefter en m\u00e5ling af hele armaturets output. Ud fra dette beregnes lysudbytteforholdet (LOR), eller armaturets optiske effektivitet.<\/p>\n<p>Filer med relativ fotometri viser b\u00e5de lyskildens (\u201clampens\u201d) lysstr\u00f8m og armaturets output. Dette har vist sig at fungere s\u00e6rligt godt for lampeteknologi, hvor en lampe testes alene, f\u00f8r den placeres i sit hus og testes separat i et goniofotometer for at bestemme tabene fra reflektorer, d\u00e6ksler osv. Det vil sige, at n\u00e5r f\u00f8rst armaturets fordeling og lampens output er kendt, er det ligetil at forst\u00e5 effekten af at \u00f8ge eller mindske lampens output p\u00e5 armaturets output. Denne funktion vises stadig i fotometrisoftware, hvor brugeren kan se kildens \u201clampelumen\u201d (uden optiske tab), og derefter \u201carmaturlumen\u201d, alts\u00e5 lysstr\u00f8mmen efter optiske tab.<\/p>\n<p>INDO bruger et goniofotometer til at m\u00e5le lampelumen (dvs. modulets output minus linsen) og hele armaturets output meget n\u00f8jagtigt.<\/p>\n<h4><\/h4>\n<h4><strong>Absolut fotometri: armaturet, hele armaturet og kun armaturet<\/strong><\/h4>\n<p>Til sammenligning er absolut fotometri en teknik, der blot m\u00e5ler et komplet armatur for at give resultater for netop den konfiguration.<\/p>\n<p><a href=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Indo-etc-053-e1569430619137.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-8959 size-medium\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Indo-etc-053-e1569430619137-225x300.jpg\" alt=\"\" width=\"225\" height=\"300\" \/><\/a><\/p>\n<p>Absolut fotometri angiver det specifikke lysstr\u00f8moutput for et specifikt armatur, som m\u00e5lt hver gang af goniofotometeret. Lysstr\u00f8moutputtet relaterer sig kun til det armatur, der testes. Da der ikke findes noget begreb om lampelumen og armaturlumen, er LOR altid lig 100% i filer med absolut fotometri.<\/p>\n<h4><strong>Hvordan p\u00e5virker denne forskel i filformat lysdesignet?<\/strong><\/h4>\n<p>Det p\u00e5virker faktisk slet ikke designet. Hvorfor? Uanset om man bruger absolutte eller relative filer, tages der automatisk h\u00f8jde for armaturets effektivitet.<\/p>\n<p>Med absolutte filer angives kun \u00e9t lysstr\u00f8moutput, og da LOR = 100%, er dette armaturets output. I en relativ fil vises lampelumen med effektivitetsfaktoren automatisk anvendt til beregningerne. Et centralt princip, der skal v\u00e6re opfyldt, for at relativ fotometri er gyldig, er, at skalering af lampens lysstr\u00f8moutput skal ske uden at p\u00e5virke lampens fotometriske fordeling. For LED-armaturer er dette faktisk tilf\u00e6ldet, n\u00e5r outputtet \u00f8ges ved at \u00f8ge LED-str\u00f8mmen, men ikke n\u00e5r det \u00f8gede output opn\u00e5s ved at tilf\u00f8je flere LED&#8217;er. I s\u00e5 fald kr\u00e6ves en ny runde fotometrisk testning.<\/p>\n<p>P\u00e5 den baggrund behandler designsoftware absolutte og relative m\u00e5linger af det samme armatur identisk, hvad ang\u00e5r fordeling, lysstr\u00f8moutput og str\u00f8mforbrug. Det betyder, at uanset om du bruger absolut eller relativ fotometri, vil resultaterne v\u00e6re identiske.<\/p>\n<p><a href=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Absolute-Calculation.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8973\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Absolute-Calculation-300x156.jpg\" alt=\"\" width=\"675\" height=\"351\" srcset=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Absolute-Calculation-300x156.jpg 300w, https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Absolute-Calculation-600x312.jpg 600w, https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Absolute-Calculation-768x400.jpg 768w, https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Absolute-Calculation.jpg 855w\" sizes=\"auto, (max-width: 675px) 100vw, 675px\" \/><\/a><\/p>\n<p><em><strong><span style=\"color: #00a5db;\">Figur A (ovenfor): viser et eksempel p\u00e5 en beregning med INDO CHANCERY-fotometri, i <span style=\"text-decoration: underline;\">Absolut<\/span> format<\/span><\/strong><\/em><\/p>\n<p><a href=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Relative-Calculation.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8975\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Relative-Calculation-300x156.jpg\" alt=\"\" width=\"675\" height=\"351\" srcset=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Relative-Calculation-300x156.jpg 300w, https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Relative-Calculation-600x312.jpg 600w, https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Relative-Calculation-768x400.jpg 768w, https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Relative-Calculation.jpg 855w\" sizes=\"auto, (max-width: 675px) 100vw, 675px\" \/><\/a><\/p>\n<p><span style=\"color: #00a5db;\"><em><strong>Figur B (ovenfor) viser den samme beregning med INDO CHANCERY-fotometri, i <span style=\"text-decoration: underline;\">Relativ<\/span> format. Bem\u00e6rk, at beregningsmetrikkerne og resultaterne er up\u00e5virkede<\/strong><\/em><\/span><\/p>\n<h4><strong>Men hvad siger standarderne?<\/strong><\/h4>\n<p>Hvad siger standarderne om forskellige m\u00e5lemetoder? IES LM-79-08 kr\u00e6ver den absolutte metode som standard testmetode, mens b\u00e5de IES LM-80-08 og IES LM-82-12 bruger den relative metode. IES TM-21-11 tager ogs\u00e5 relative formatdata fra LM-80 og ekstrapolerer dem til at beregne armaturets levetid. Armaturer b\u00f8r fotometrisk testes efter LM-79, men andre standarder kr\u00e6ver alternativ testning.<\/p>\n<h4><strong>Konklusion<\/strong><\/h4>\n<p>Nogle vil m\u00e5ske foresl\u00e5, at ikke blot b\u00f8r den absolutte metode bruges til at m\u00e5le armaturer, men at det samme armatur, der k\u00f8rer ved en lavere watt, kr\u00e6ver en separat absolut test. Men hvis antallet og placeringen af LED&#8217;er ikke \u00e6ndres, \u00e6ndres den fotometriske fordeling heller ikke.<\/p>\n<p>I s\u00e5 fald er relativ fotometri det mere omkostningseffektive og lettere anvendelige format, ikke mindst fordi det tillader hurtig skalering under lysdesign. I forbindelse med d\u00e6mpning er det, n\u00e5r LED&#8217;er d\u00e6mpes ned, kun n\u00f8dvendigt at tage h\u00f8jde for det reducerede lysstr\u00f8moutput i lysdesignet.<\/p>\n<p>Hvis der leveres forskellige absolutte fotometrifiler for forskellige outputniveauer af det samme armatur, er antydningen, at en designer ville skulle indl\u00e6se en ny fotometrisk fordeling, hver gang et d\u00e6mpningsregime overvejes. Dette skaber igen un\u00f8dvendigt ekstraarbejde og omkostninger, hvilket simpelthen ikke giver mening.<\/p>\n<p>At forst\u00e5 fotometriske data kr\u00e6ver f\u00f8rst og fremmest kommunikation med producenterne: at finde ud af, hvilken slags fotometri der leveres, hvordan den er testet, og hvorfor den blev testet p\u00e5 den m\u00e5de. Nogle vil m\u00e5ske sige, at det ene format er mere fordelagtigt end det andet og b\u00f8r bruges isoleret. Men som du kan se, beh\u00f8ver sandheden ikke v\u00e6re s\u00e5 absolut!<\/p>\n<p>Kilder:<\/p>\n<p><a href=\"https:\/\/www.lightingreality.com\/\" target=\"_blank\" rel=\"noopener noreferrer\">https:\/\/www.lightingreality.com\/<\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Lawrence Baynham og Toby Penter ser n\u00e6rmere p\u00e5 de to m\u00e5der at pr\u00e6sentere vejbelysningsproducenters data p\u00e5. N\u00e5r man designer en vejbelysningsinstallation, er kvaliteten og n\u00f8jagtigheden af de fotometriske data af allerst\u00f8rste betydning. Du er sikkert klar over, at producenters data kan pr\u00e6senteres i to formater: absolut fotometri og relativ fotometri. Men hvilket format b\u00f8r du [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":8957,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[129],"tags":[131],"class_list":["post-22823","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-exterior-lighting"],"_links":{"self":[{"href":"https:\/\/indolighting.com\/da\/wp-json\/wp\/v2\/posts\/22823","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/indolighting.com\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/indolighting.com\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/indolighting.com\/da\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/indolighting.com\/da\/wp-json\/wp\/v2\/comments?post=22823"}],"version-history":[{"count":2,"href":"https:\/\/indolighting.com\/da\/wp-json\/wp\/v2\/posts\/22823\/revisions"}],"predecessor-version":[{"id":23540,"href":"https:\/\/indolighting.com\/da\/wp-json\/wp\/v2\/posts\/22823\/revisions\/23540"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/indolighting.com\/da\/wp-json\/wp\/v2\/media\/8957"}],"wp:attachment":[{"href":"https:\/\/indolighting.com\/da\/wp-json\/wp\/v2\/media?parent=22823"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/indolighting.com\/da\/wp-json\/wp\/v2\/categories?post=22823"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/indolighting.com\/da\/wp-json\/wp\/v2\/tags?post=22823"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}