{"id":21143,"date":"2023-10-18T23:37:01","date_gmt":"2023-10-18T22:37:01","guid":{"rendered":"http:\/\/indolighting.com\/?p=21143"},"modified":"2026-05-11T20:51:00","modified_gmt":"2026-05-11T19:51:00","slug":"introduction-a-la-protection-contre-les-surtensions","status":"publish","type":"post","link":"https:\/\/indolighting.com\/fr\/introduction-a-la-protection-contre-les-surtensions\/","title":{"rendered":"Introduction \u00e0 la protection contre les surtensions"},"content":{"rendered":"<h5><span style=\"color: #00a5db;\">Si vous envisagez une mise \u00e0 niveau ou souhaitez vous assurer que vos d\u00e9cisions d&rsquo;achat sont bien \u00e9clair\u00e9es, voici une introduction pratique aux MOV et aux syst\u00e8mes de protection contre les surtensions dont les luminaires ont besoin.<\/span><\/h5>\n<h5><span style=\"color: #f29621;\">Que sont les MOV ?<\/span><\/h5>\n<figure id=\"attachment_2908\" aria-describedby=\"caption-attachment-2908\" style=\"width: 334px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/indolighting.com\/wp-content\/uploads\/2016\/05\/metal-oxide-varistors.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2908\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2016\/05\/metal-oxide-varistors.jpg\" alt=\"Varistor iTMOV TMOV Image\" width=\"334\" height=\"334\" srcset=\"https:\/\/indolighting.com\/wp-content\/uploads\/2016\/05\/metal-oxide-varistors.jpg 334w, https:\/\/indolighting.com\/wp-content\/uploads\/2016\/05\/metal-oxide-varistors-100x100.jpg 100w, https:\/\/indolighting.com\/wp-content\/uploads\/2016\/05\/metal-oxide-varistors-300x300.jpg 300w, https:\/\/indolighting.com\/wp-content\/uploads\/2016\/05\/metal-oxide-varistors-150x150.jpg 150w\" sizes=\"auto, (max-width: 334px) 100vw, 334px\" \/><\/a><figcaption id=\"caption-attachment-2908\" class=\"wp-caption-text\"><em>Image Varistor iTMOV TMOV, avec l&rsquo;aimable autorisation de Littelfuse<\/em><\/figcaption><\/figure>\n<p>Les varistances \u00e0 oxyde m\u00e9tallique (MOV) constituent une solution efficace pour \u00e9cr\u00eater les surtensions et les surtensions transitoires en tant que premier \u00e9tage de protection des \u00e9quipements d&rsquo;\u00e9clairage. En termes simples, le MOV conduit le courant lors d&rsquo;une surtension et absorbe de grandes quantit\u00e9s d&rsquo;\u00e9nergie de d\u00e9faut pour prot\u00e9ger l&rsquo;\u00e9quipement connect\u00e9 localement.<\/p>\n<p>En fonctionnement normal, le MOV est un composant passif qui se connecte entre la phase et le neutre pour les surtensions en mode diff\u00e9rentiel, et entre la phase ou le neutre et la terre pour les surtensions en mode commun.<\/p>\n<p>Pour une tension de fonctionnement nominale donn\u00e9e, la taille physique du MOV indique sa valeur nominale (c&rsquo;est-\u00e0-dire le courant de d\u00e9charge maximal) ; les MOV de plus grande taille peuvent g\u00e9n\u00e9ralement encaisser davantage d&rsquo;impulsions \u00e0 une tension de surtension donn\u00e9e avant de s&rsquo;user. Une autre caract\u00e9ristique importante de tout MOV est sa courbe \u00ab V-I \u00bb, c&rsquo;est-\u00e0-dire le niveau de courant conduit \u00e0 diff\u00e9rentes surtensions pour prot\u00e9ger l&rsquo;\u00e9quipement connect\u00e9. Cette courbe nous indique notamment \u00e0 quel moment le MOV conduira un courant significatif.<\/p>\n<h5><span style=\"color: #f29621;\">Pourquoi la protection secondaire est-elle importante ?<\/span><\/h5>\n<p>Il est important de noter que lors d&rsquo;un \u00e9v\u00e9nement de surtension, le MOV \u00ab \u00e9cr\u00eate \u00bb la tension de surtension. Cette tension \u00e9cr\u00eat\u00e9e sera transmise \u00e0 l&rsquo;\u00e9quipement d&rsquo;\u00e9clairage. La protection secondaire au sein de l&rsquo;\u00e9quipement (ou l&rsquo;\u00e9quipement lui-m\u00eame) doit donc \u00eatre capable de supporter cette tension \u00e9cr\u00eat\u00e9e (qui peut avoisiner les 1 000 V). Une protection secondaire mal con\u00e7ue peut entra\u00eener des d\u00e9faillances des \u00e9quipements d&rsquo;\u00e9clairage avant m\u00eame que les MOV n&rsquo;arrivent en fin de vie.<\/p>\n<h5><span style=\"color: #f29621;\">Comprendre un syst\u00e8me MOV \u00e9quilibr\u00e9<\/span><\/h5>\n<p>Les syst\u00e8mes de protection compos\u00e9s de plusieurs MOV (ou parasurtenseurs) doivent \u00eatre soigneusement \u00e9tudi\u00e9s pour \u00eatre efficaces. \u00c0 d\u00e9faut, le syst\u00e8me ne sera protecteur qu&rsquo;\u00e0 hauteur du MOV le plus faible. La raison en est que diff\u00e9rents MOV auront in\u00e9vitablement des courbes V-I diff\u00e9rentes, que ce soit en raison des valeurs des composants, des diff\u00e9rences entre fabricants ou encore entre lots de production.<\/p>\n<figure id=\"attachment_2904\" aria-describedby=\"caption-attachment-2904\" style=\"width: 719px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2904\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2016\/05\/V-I-MOV.png\" alt=\"A V-I curve\" width=\"719\" height=\"397\" srcset=\"https:\/\/indolighting.com\/wp-content\/uploads\/2016\/05\/V-I-MOV.png 1580w, https:\/\/indolighting.com\/wp-content\/uploads\/2016\/05\/V-I-MOV-600x331.png 600w, https:\/\/indolighting.com\/wp-content\/uploads\/2016\/05\/V-I-MOV-300x165.png 300w, https:\/\/indolighting.com\/wp-content\/uploads\/2016\/05\/V-I-MOV-1024x564.png 1024w, https:\/\/indolighting.com\/wp-content\/uploads\/2016\/05\/V-I-MOV-768x423.png 768w, https:\/\/indolighting.com\/wp-content\/uploads\/2016\/05\/V-I-MOV-1536x847.png 1536w\" sizes=\"auto, (max-width: 719px) 100vw, 719px\" \/><figcaption id=\"caption-attachment-2904\" class=\"wp-caption-text\"><em>Une courbe V-I repr\u00e9sente la conduction \u00e0 diff\u00e9rentes tensions de surtension<\/em><\/figcaption><\/figure>\n<p>Pour les luminaires dot\u00e9s d&rsquo;un seul parasurtenseur (SPD), il peut sembler qu&rsquo;il n&rsquo;y ait pas de syst\u00e8me \u00e0 prendre en compte. Cependant, de nombreux appareils connect\u00e9s contiennent des MOV entre la phase et le neutre, comme la cellule photovolta\u00efque et le driver LED. Si le syst\u00e8me est correctement con\u00e7u, il peut \u00eatre possible d&rsquo;avoir des composants assez bien appari\u00e9s, ce qui signifie que la surtension est partag\u00e9e entre la cellule, le SPD et le driver. En revanche, si le syst\u00e8me <span style=\"text-decoration: underline;\">n&rsquo;est pas<\/span> bien appari\u00e9, la totalit\u00e9 de la surtension risque d&rsquo;\u00eatre absorb\u00e9e par le MOV le plus petit (par exemple, celui de la cellule), ce qui peut provoquer un fonctionnement diurne ou une d\u00e9faillance du luminaire.<\/p>\n<p>Il s&rsquo;agit d&rsquo;une consid\u00e9ration critique lors d&rsquo;une mise \u00e0 niveau ou du remplacement d&rsquo;un composant individuel, comme un driver LED d\u00e9faillant. Dans ce cas, vous pourriez vous retrouver avec un luminaire contenant un MOV de 5 kA dans le driver et un MOV plus petit de 2 kA dans la cellule, les deux ayant \u00e9t\u00e9 initialement s\u00e9lectionn\u00e9s pour assurer un partage \u00e9quilibr\u00e9 de la surtension. Apr\u00e8s la d\u00e9faillance, si le driver LED est remplac\u00e9 par un mod\u00e8le \u00e9quip\u00e9 d&rsquo;un MOV de 10 kA avec une courbe VI diff\u00e9rente, le r\u00e9sultat final pourrait bien \u00eatre que <span style=\"text-decoration: underline;\">davantage<\/span> de surtension soit d\u00e9vi\u00e9e vers le MOV de 2 kA de la cellule qu&rsquo;avant la mise \u00e0 niveau ! Dans ce cas, la modification a abouti \u00e0 un syst\u00e8me offrant une protection significativement inf\u00e9rieure \u00e0 celle dont il disposait auparavant.<\/p>\n<h5><span style=\"color: #f29621;\">En r\u00e9sum\u00e9&#8230;<\/span><\/h5>\n<p>En d\u00e9finitive, les complexit\u00e9s sont nombreuses. Veiller \u00e0 la mise en place de mesures secondaires adapt\u00e9es, associ\u00e9es \u00e0 une approche syst\u00e8me globale tout au long de la vie du luminaire, est imp\u00e9ratif pour garantir un fonctionnement fiable et la protection des luminaires.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Si vous envisagez une mise \u00e0 niveau ou souhaitez vous assurer que vos d\u00e9cisions d&rsquo;achat sont bien \u00e9clair\u00e9es, voici une introduction pratique aux MOV et aux syst\u00e8mes de protection contre les surtensions dont les luminaires ont besoin. Que sont les MOV ? Les varistances \u00e0 oxyde m\u00e9tallique (MOV) constituent une solution efficace pour \u00e9cr\u00eater les [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":19484,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[129],"tags":[],"class_list":["post-21143","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/indolighting.com\/fr\/wp-json\/wp\/v2\/posts\/21143","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/indolighting.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/indolighting.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/indolighting.com\/fr\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/indolighting.com\/fr\/wp-json\/wp\/v2\/comments?post=21143"}],"version-history":[{"count":2,"href":"https:\/\/indolighting.com\/fr\/wp-json\/wp\/v2\/posts\/21143\/revisions"}],"predecessor-version":[{"id":22106,"href":"https:\/\/indolighting.com\/fr\/wp-json\/wp\/v2\/posts\/21143\/revisions\/22106"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/indolighting.com\/fr\/wp-json\/wp\/v2\/media\/19484"}],"wp:attachment":[{"href":"https:\/\/indolighting.com\/fr\/wp-json\/wp\/v2\/media?parent=21143"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/indolighting.com\/fr\/wp-json\/wp\/v2\/categories?post=21143"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/indolighting.com\/fr\/wp-json\/wp\/v2\/tags?post=21143"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}