{"id":24284,"date":"2023-10-18T23:36:51","date_gmt":"2023-10-18T22:36:51","guid":{"rendered":"http:\/\/indolighting.com\/?p=24284"},"modified":"2026-09-29T20:15:22","modified_gmt":"2026-09-29T19:15:22","slug":"fotometrija-absoliucioji-ar-santykine","status":"publish","type":"post","link":"https:\/\/indolighting.com\/lt\/fotometrija-absoliucioji-ar-santykine\/","title":{"rendered":"Fotometrija: absoliu\u010dioji ar santykin\u0117?"},"content":{"rendered":"<h4><span style=\"color: #00a5db;\">Lawrence Baynham ir Toby Penter ap\u017evelgia du gatvi\u0173 \u0161viestuv\u0173 gamintoj\u0173 duomen\u0173 pateikimo b\u016bdus.<\/span><\/h4>\n<p><strong>Projektuojant gatvi\u0173 ap\u0161vietimo \u012frengin\u012f, fotometrini\u0173 duomen\u0173 kokyb\u0117 ir tikslumas yra be galo svarb\u016bs. Tikriausiai \u017einote, kad gamintoj\u0173 duomenys gali b\u016bti pateikiami dviem formatais: absoliu\u010diosios fotometrijos ir santykin\u0117s fotometrijos. Bet kur\u012f format\u0105 naudoti? Ar vienas tikslesnis u\u017e kit\u0105?<\/strong><\/p>\n<p>Trumpas atsakymas: ne, abu duoda tuos pa\u010dius rezultatus. Panagrin\u0117kime abu b\u016bdus i\u0161samiau ir supraskime, kod\u0117l taip yra.<\/p>\n<h4><strong>Santykin\u0117 fotometrija: element\u0173 i\u0161skaidymas<\/strong><\/h4>\n<p>Santykin\u0117 fotometrija pagr\u012fsta tuo, kad atskirai i\u0161matuojamas \u0161viesos \u0161altinis (arba \u201elempa\u201c), o paskui viso \u0161viestuvo \u0161viesos srautas. I\u0161 \u0161i\u0173 duomen\u0173 apskai\u010diuojamas \u0161viestuvo naudingumo koeficientas (LOR), arba optinis \u0161viestuvo efektyvumas.<\/p>\n<p>Santykin\u0117s fotometrijos failuose nurodomas ir \u201elempos\u201c \u0161viesos srautas, ir \u0161viestuvo \u0161viesos srautas. \u012erodyta, kad \u0161is b\u016bdas ypa\u010d gerai tinka lemp\u0173 technologijai, kai lempa pirmiausia i\u0161bandoma atskirai, o paskui \u012fstatoma \u012f korpus\u0105 ir atskirai i\u0161bandoma goniofotometru, siekiant nustatyti at\u0161vait\u0173, gaubt\u0173 ir kit\u0173 dali\u0173 nuostolius. T. y. \u017einant \u0161viestuvo \u0161viesos skirstin\u012f ir lempos \u0161viesos sraut\u0105, nesunku suprasti, kaip lempos srauto didinimas ar ma\u017einimas paveiks \u0161viestuvo sraut\u0105. \u0160i funkcija vis dar rodoma fotometrijos programose: naudotojas mato \u0161altinio \u201elempos liumenus\u201c (be optini\u0173 nuostoli\u0173) ir \u201e\u0161viestuvo liumenus\u201c, t. y. \u0161viesos sraut\u0105 po optini\u0173 nuostoli\u0173.<\/p>\n<p>INDO goniofotometru labai tiksliai matuoja lempos liumenus (t. y. modulio sraut\u0105 be l\u0119\u0161io) ir viso \u0161viestuvo \u0161viesos sraut\u0105.<\/p>\n<h4><\/h4>\n<h4><strong>Absoliu\u010dioji fotometrija: \u0161viestuvas, visas \u0161viestuvas ir tik \u0161viestuvas<\/strong><\/h4>\n<p>Absoliu\u010dioji fotometrija, prie\u0161ingai, yra metodas, kai tiesiog matuojamas visas \u0161viestuvas ir gaunami b\u016btent tos konfig\u016bracijos rezultatai.<\/p>\n<p><a href=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Indo-etc-053-e1569430619137.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-8959 size-medium\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Indo-etc-053-e1569430619137-225x300.jpg\" alt=\"\" width=\"225\" height=\"300\" \/><\/a><\/p>\n<p>Absoliu\u010dioji fotometrija pateikia konkretaus \u0161viestuvo \u0161viesos sraut\u0105, kiekvien\u0105 kart\u0105 i\u0161matuot\u0105 goniofotometru. \u0160viesos srautas susij\u0119s tik su bandomu \u0161viestuvu. Kadangi lempos liumen\u0173 ir \u0161viestuvo liumen\u0173 s\u0105vok\u0173 n\u0117ra, absoliu\u010diosios fotometrijos failuose LOR visada lygus 100 %.<\/p>\n<h4><strong>Kaip \u0161is fail\u0173 formato skirtumas veikia ap\u0161vietimo projektavim\u0105?<\/strong><\/h4>\n<p>I\u0161 tikr\u0173j\u0173 projektavimui jis visi\u0161kai neturi \u012ftakos. Kod\u0117l? Naudojant tiek absoliu\u010diosios, tiek santykin\u0117s fotometrijos failus, \u0161viestuvo efektyvumas \u012fvertinamas automati\u0161kai.<\/p>\n<p>Absoliu\u010diosios fotometrijos failuose nurodomas tik vienas \u0161viesos srautas, o kadangi LOR = 100 %, tai ir yra \u0161viestuvo srautas. Santykiniame faile rodomi lempos liumenai, o skai\u010diavimams automati\u0161kai pritaikomas efektyvumo koeficientas. Pagrindin\u0117 s\u0105lyga, kad santykin\u0117 fotometrija b\u016bt\u0173 pagr\u012fsta: kei\u010diant lempos \u0161viesos sraut\u0105, neturi keistis lempos fotometrinis skirstinys. LED \u0161viestuvams tai tiesa, kai srautas didinamas didinant LED srov\u0119, bet netiesa, kai didesnis srautas pasiekiamas pridedant daugiau LED. Tokiu atveju reikia nauj\u0173 fotometrini\u0173 bandym\u0173.<\/p>\n<p>Tod\u0117l projektavimo programos to paties \u0161viestuvo absoliu\u010diuosius ir santykinius matavimus traktuoja vienodai pagal skirstin\u012f, \u0161viesos sraut\u0105 ir vartojam\u0105 gali\u0105. Tai rei\u0161kia, kad nesvarbu, ar naudojate absoliu\u010di\u0105j\u0105, ar santykin\u0119 fotometrij\u0105, rezultatai bus vienodi.<\/p>\n<p><a href=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Absolute-Calculation.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8973\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Absolute-Calculation-300x156.jpg\" alt=\"\" width=\"675\" height=\"351\" srcset=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Absolute-Calculation-300x156.jpg 300w, https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Absolute-Calculation-600x312.jpg 600w, https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Absolute-Calculation-768x400.jpg 768w, https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Absolute-Calculation.jpg 855w\" sizes=\"auto, (max-width: 675px) 100vw, 675px\" \/><\/a><\/p>\n<p><em><strong><span style=\"color: #00a5db;\">A paveikslas (vir\u0161uje): skai\u010diavimo pavyzdys, naudojant INDO CHANCERY fotometrij\u0105 <span style=\"text-decoration: underline;\">absoliu\u010diuoju<\/span> formatu<\/span><\/strong><\/em><\/p>\n<p><a href=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Relative-Calculation.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-8975\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Relative-Calculation-300x156.jpg\" alt=\"\" width=\"675\" height=\"351\" srcset=\"https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Relative-Calculation-300x156.jpg 300w, https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Relative-Calculation-600x312.jpg 600w, https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Relative-Calculation-768x400.jpg 768w, https:\/\/indolighting.com\/wp-content\/uploads\/2019\/09\/Relative-Calculation.jpg 855w\" sizes=\"auto, (max-width: 675px) 100vw, 675px\" \/><\/a><\/p>\n<p><span style=\"color: #00a5db;\"><em><strong>B paveikslas (vir\u0161uje): tas pats skai\u010diavimas, naudojant INDO CHANCERY fotometrij\u0105 <span style=\"text-decoration: underline;\">santykiniu<\/span> formatu. Atkreipkite d\u0117mes\u012f, kad skai\u010diavimo rodikliai ir rezultatai nepasikeit\u0117<\/strong><\/em><\/span><\/p>\n<h4><strong>O k\u0105 sako standartai?<\/strong><\/h4>\n<p>K\u0105 standartai sako apie skirtingus matavimo metodus? IES LM-79-08 standartiniu bandym\u0173 metodu laiko absoliu\u010di\u0105j\u012f metod\u0105, o IES LM-80-08 ir IES LM-82-12 naudoja santykin\u012f metod\u0105. IES TM-21-11 taip pat ima santykinio formato LM-80 duomenis ir juos ekstrapoliuoja \u0161viestuvo tarnavimo laikui apskai\u010diuoti. \u0160viestuv\u0173 fotometriniai bandymai tur\u0117t\u0173 b\u016bti atliekami pagal LM-79, ta\u010diau kiti standartai reikalauja kitoki\u0173 bandym\u0173.<\/p>\n<h4><strong>I\u0161vados<\/strong><\/h4>\n<p>Kai kas gali teigti ne tik tai, kad \u0161viestuvams matuoti tur\u0117t\u0173 b\u016bti naudojamas absoliutusis metodas, bet ir tai, kad tam pa\u010diam \u0161viestuvui, veikian\u010diam ma\u017eesne galia, reikia atskiro absoliu\u010diojo bandymo. Ta\u010diau jei LED skai\u010dius ir i\u0161d\u0117stymas nesikei\u010dia, nesikei\u010dia ir fotometrinis skirstinys.<\/p>\n<p>\u0160iuo atveju santykin\u0117 fotometrija yra ekonomi\u0161kesnis ir patogesnis formatas, ypa\u010d tod\u0117l, kad leid\u017eia greitai keisti sraut\u0105 projektuojant ap\u0161vietim\u0105. Kalbant apie pritemdym\u0105, pritemd\u017eius LED, ap\u0161vietimo projekte tereikia \u012fvertinti suma\u017e\u0117jus\u012f \u0161viesos sraut\u0105.<\/p>\n<p>Jei tam pa\u010diam \u0161viestuvui pateikiami skirtingi absoliu\u010diosios fotometrijos failai skirtingiems srauto lygiams, tai rei\u0161kia, kad projektuotojui tekt\u0173 \u012fkelti nauj\u0105 fotometrin\u012f skirstin\u012f kaskart, kai svarstomas pritemdymo re\u017eimas. Tai v\u0117l sukuria nereikaling\u0105 papildom\u0105 darb\u0105 ir i\u0161laidas, o tai tiesiog nelogi\u0161ka.<\/p>\n<p>Norint suprasti fotometrinius duomenis, pirmiausia reikia bendrauti su gamintojais: i\u0161siai\u0161kinti, kokia fotometrija pateikiama, kaip ji buvo i\u0161bandyta ir kod\u0117l b\u016btent taip. Kai kas gali teigti, kad vienas formatas naudingesnis u\u017e kit\u0105 ir tur\u0117t\u0173 b\u016bti naudojamas vienas. Ta\u010diau, kaip matote, tiesa neprivalo b\u016bti tokia absoliuti!<\/p>\n<p>\u0160altiniai:<\/p>\n<p><a href=\"https:\/\/www.lightingreality.com\/\" target=\"_blank\" rel=\"noopener noreferrer\">https:\/\/www.lightingreality.com\/<\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Lawrence Baynham ir Toby Penter ap\u017evelgia du gatvi\u0173 \u0161viestuv\u0173 gamintoj\u0173 duomen\u0173 pateikimo b\u016bdus. Projektuojant gatvi\u0173 ap\u0161vietimo \u012frengin\u012f, fotometrini\u0173 duomen\u0173 kokyb\u0117 ir tikslumas yra be galo svarb\u016bs. Tikriausiai \u017einote, kad gamintoj\u0173 duomenys gali b\u016bti pateikiami dviem formatais: absoliu\u010diosios fotometrijos ir santykin\u0117s fotometrijos. Bet kur\u012f format\u0105 naudoti? Ar vienas tikslesnis u\u017e kit\u0105? Trumpas atsakymas: ne, abu duoda [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":8957,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[129],"tags":[131],"class_list":["post-24284","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-exterior-lighting"],"_links":{"self":[{"href":"https:\/\/indolighting.com\/lt\/wp-json\/wp\/v2\/posts\/24284","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/indolighting.com\/lt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/indolighting.com\/lt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/indolighting.com\/lt\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/indolighting.com\/lt\/wp-json\/wp\/v2\/comments?post=24284"}],"version-history":[{"count":1,"href":"https:\/\/indolighting.com\/lt\/wp-json\/wp\/v2\/posts\/24284\/revisions"}],"predecessor-version":[{"id":24285,"href":"https:\/\/indolighting.com\/lt\/wp-json\/wp\/v2\/posts\/24284\/revisions\/24285"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/indolighting.com\/lt\/wp-json\/wp\/v2\/media\/8957"}],"wp:attachment":[{"href":"https:\/\/indolighting.com\/lt\/wp-json\/wp\/v2\/media?parent=24284"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/indolighting.com\/lt\/wp-json\/wp\/v2\/categories?post=24284"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/indolighting.com\/lt\/wp-json\/wp\/v2\/tags?post=24284"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}