{"id":20527,"date":"2023-10-18T23:36:52","date_gmt":"2023-10-18T22:36:52","guid":{"rendered":"http:\/\/indolighting.com\/?p=20527"},"modified":"2026-05-11T20:51:01","modified_gmt":"2026-05-11T19:51:01","slug":"b50-eller-inte-b50-underhallsfaktorer-for-led","status":"publish","type":"post","link":"https:\/\/indolighting.com\/sv\/b50-eller-inte-b50-underhallsfaktorer-for-led\/","title":{"rendered":"B50 eller inte B50, underh\u00e5llsfaktorer f\u00f6r LED"},"content":{"rendered":"<p><strong><span style=\"color: #00a5db;\">N\u00e4r man v\u00e4ljer r\u00e4tt ljusfl\u00f6desm\u00e4ssiga underh\u00e5llsfaktorer f\u00f6r LED-gatubelysning \u00e4r det avg\u00f6rande att ta h\u00e4nsyn till r\u00e4tt m\u00e4ngd ljusfl\u00f6desdegradation f\u00f6r att s\u00e4kerst\u00e4lla att ett belysningsprojekt uppfyller kraven vid slutet av sin livsl\u00e4ngd. St\u00e4ller belysningsproffs r\u00e4tt fr\u00e5gor till sina leverant\u00f6rer?<\/span><\/strong><\/p>\n<p>Det \u00e4r v\u00e4lk\u00e4nt att LED:ens ljusutstr\u00f6m minskar \u00f6ver tid, det som kallas ljusfl\u00f6desdegradation. F\u00f6r att s\u00e4kerst\u00e4lla att ett belysningsprojekt uppfyller kraven \u00e4ven vid slutet av sin livsl\u00e4ngd m\u00e5ste vi d\u00e4rf\u00f6r ta h\u00e4nsyn till denna ljusfl\u00f6desdegradation under armaturen livstid.<\/p>\n<p>Genom att g\u00f6ra detta f\u00e5r vi antingen mer ljus \u00e4n vad som kr\u00e4vs i b\u00f6rjan av livscykeln, eller s\u00e5 anv\u00e4nder vi en metod med konstant ljusutstr\u00f6m (CLO) f\u00f6r att leverera konsistenta niv\u00e5er under perioden, genom att starta enheten i ett dimmrat l\u00e4ge och gradvis \u00f6ka till maximal effekt under drifttiden.<\/p>\n<p>S\u00e5 l\u00e5ngt, s\u00e5 bra. Vi har tv\u00e5 tydliga val f\u00f6r hur vi hanterar ljusfl\u00f6desdegradation, och dessa \u00e4r l\u00e4ttillg\u00e4ngliga fr\u00e5n alla stora belysingstillverkare.<\/p>\n<h4>V\u00e4lja r\u00e4tt CLO-profil<\/h4>\n<p>En faktor som l\u00e4tt kan f\u00f6rbises \u00e4r dock att matcha CLO-algoritmen till den planerade livsl\u00e4ngden f\u00f6r projektet.<\/p>\n<p><a href=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/report.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-thumbnail wp-image-6990 alignleft\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/report-150x150.png\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/report-150x150.png 150w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/report-100x100.png 100w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/report-300x300.png 300w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/report.png 512w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>Om projektets konstruktionslivsl\u00e4ngd \u00e4r, s\u00e4g, 100 000 timmar och vi vet att en enhets LED-utstr\u00f6m efter denna tid \u00e4r 80 % av sitt ursprungliga v\u00e4rde, b\u00f6r armaturerna vid installation starta p\u00e5 80 % utstr\u00f6m och \u00f6ka effekten s\u00e5 att den n\u00e5r 100 % efter 100 000 timmar.<\/p>\n<p>P\u00e5 motsvarande s\u00e4tt, om en projektlivsl\u00e4ngd \u00e4r 60 000 timmar och samma produkt har 88 % av sin utstr\u00f6m efter denna period, b\u00f6r CLO-algoritmen starta p\u00e5 88 % utstr\u00f6m och \u00f6ka till 100 % utstr\u00f6m under 60 000-timmarsperioden.<\/p>\n<p>F\u00f6r en typisk LED-lykta med L80 p\u00e5 100 000 timmar kan CLO spara 10 % av livscykelns energikostnader under perioden.<\/p>\n<p><a href=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/Resert.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-thumbnail wp-image-6992\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/Resert-150x150.png\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/Resert-150x150.png 150w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/Resert-100x100.png 100w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/Resert.png 200w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a>Det \u00e4r vanligt att armaturtillverkare st\u00e4ller in en standard-CLO-algoritm <em>som f\u00f6ruts\u00e4tter att projektlivsl\u00e4ngden \u00e4r lika med produktlivsl\u00e4ngden<\/em>. Det \u00e4r viktigt att vara medveten om detta s\u00e5 att CLO-profilen kan matchas korrekt mot installationen.<\/p>\n<p>Gl\u00f6m heller inte att n\u00e4r CLO-program anv\u00e4nds i LED-drivdon, om ett drivareutbyte blir n\u00f6dv\u00e4ndigt, kommer CLO-algoritmen att \u00e5terst\u00e4llas och starta om fr\u00e5n &#8221;livscykelns b\u00f6rjan&#8221; om den inte programmeras enhet f\u00f6r enhet! Detta kommer att resultera i ett underbelyst, och d\u00e4rmed icke-regelenligt, projekt.<\/p>\n<h4>Att f\u00f6rst\u00e5 LED-livsl\u00e4ngder och underh\u00e5llsfaktorer f\u00f6r LED-gatubelysning<\/h4>\n<p>Hur vet vi d\u00e5 vad LED:ens utstr\u00f6m \u00e4r vid projektets slut?<\/p>\n<p>Det finns flera modeller som kan anv\u00e4ndas f\u00f6r att projicera ljusfl\u00f6desutstr\u00f6m, s\u00e5 att vi kan f\u00f6ruts\u00e4ga vilken ljusutstr\u00f6m som kommer att finnas efter en given drifttid. Dessa metoder bygger p\u00e5 uppm\u00e4tt data och anv\u00e4nder sedan matematiska modeller f\u00f6r att f\u00f6rutse hur LED:arna kommer att prestera i framtiden baserat p\u00e5 observerad prestanda under testperioden.<\/p>\n<p>TM-21<a href=\"#_ftn1\" name=\"_ftnref1\">[1]<\/a> \u00e4r en s\u00e5dan ber\u00e4kning och anv\u00e4nds ofta inom belysningsbranschen. Ber\u00e4kningen baseras p\u00e5 data insamlade enligt LM-80<a href=\"#_ftn2\" name=\"_ftnref2\">[2]<\/a>-resultaten f\u00f6r LED:arna.<\/p>\n<h4>LM-80 = Testning<\/h4>\n<h4><strong><a href=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/Integrated-sphere-LM-80-test.jpeg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-6980 size-medium\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/Integrated-sphere-LM-80-test-300x200.jpeg\" alt=\"lumen maintenance testing equipment for LED fittings\" width=\"300\" height=\"200\" srcset=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/Integrated-sphere-LM-80-test-300x200.jpeg 300w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/Integrated-sphere-LM-80-test-600x400.jpeg 600w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/Integrated-sphere-LM-80-test-768x512.jpeg 768w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/Integrated-sphere-LM-80-test.jpeg 960w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/strong><\/h4>\n<p>LM-80 \u00e4r en teststandard som definierar hur ett LED-paket, en array eller en modul ska testas samt hur resultaten ska samlas in.<\/p>\n<p>Metoden inneb\u00e4r att LED-proverna monteras i en testkammare med noggrant kontrollerade omgivningsf\u00f6rh\u00e5llanden och elektriska insignaler, varefter enheterna m\u00e4ts periodiskt f\u00f6r ljusutstr\u00f6m och kromaticitet.<\/p>\n<p>Testets varaktighet m\u00e5ste vara minst 6 000 timmar och forts\u00e4tts vanligtvis under en mycket l\u00e4ngre period f\u00f6r att f\u00f6rb\u00e4ttra projektionernas noggrannhet och giltighet. Testning utf\u00f6rs vid en LED-h\u00f6ljtemperatur p\u00e5 55 grader, 85 grader och en tredje temperatur vald av tillverkaren. Data m\u00e5ste samlas in minst var 1 000:e timme vid 25 grader.<\/p>\n<p>LM-80 \u00e4r bara en tillf\u00f6rlitlig informationsk\u00e4lla som ger kunderna m\u00f6jlighet att utv\u00e4rdera och j\u00e4mf\u00f6ra ljusfl\u00f6desm\u00e4ssiga underh\u00e5llsfaktorer f\u00f6r LED-gatubelysningsenheter fr\u00e5n olika tillverkare. Det \u00e4r dock inte ett fullst\u00e4ndigt m\u00e5tt p\u00e5 LED-systemets prestanda eller tillf\u00f6rlitlighet.<\/p>\n<p>Det \u00e4r v\u00e4rt att notera att om drivdonets livsl\u00e4ngd \u00e4r kortare \u00e4n modulens kan ett drivdonsbyte bli n\u00f6dv\u00e4ndigt innan armaturen har fullgjort sin livscykel. Det inneb\u00e4r att man inte kan ange ett enda v\u00e4rde f\u00f6r armaturen totala livsl\u00e4ngd. Modulens och drivdonets v\u00e4rden ska deklareras separat och inte kombineras.<\/p>\n<h4>TM-21 = Projektioner<\/h4>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-thumbnail wp-image-6978 alignleft\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/Chart-Plot-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/Chart-Plot-150x150.jpg 150w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/Chart-Plot-100x100.jpg 100w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/Chart-Plot-500x497.jpg 500w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/>TM-21 utvecklades f\u00f6r att extrapolera dessa kortsiktiga LED-komponenttestdata f\u00f6r att f\u00f6ruts\u00e4ga framtida livsl\u00e4ngder och ge s\u00e4kerhet om tekniken.<\/p>\n<p>F\u00f6r att f\u00f6ruts\u00e4ga ljusfl\u00f6desdegradation kr\u00e4ver TM-21 helt enkelt att genomsnittlig ljusutstr\u00f6m (som en procentandel av den initiala ljusutstr\u00f6mmen) f\u00f6r de testade LED:arna registreras vid olika j\u00e4mnt f\u00f6rdelade tidpunkter under testet.<\/p>\n<p>Projektionsmetoden kan sedan anv\u00e4ndas f\u00f6r att f\u00f6ruts\u00e4ga ljusfl\u00f6desdegradation efter en period, eller f\u00f6ruts\u00e4ga antalet drifttimmar som kommer att f\u00f6rflyta innan ljusutstr\u00f6mmen n\u00e5r en definierad degradationsniv\u00e5.<\/p>\n<figure id=\"attachment_6868\" aria-describedby=\"caption-attachment-6868\" style=\"width: 600px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/B50-2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-6868\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/B50-2-300x270.png\" alt=\"Chart showing lumen maintenance results\" width=\"600\" height=\"540\" srcset=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/B50-2-300x270.png 300w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/B50-2-600x540.png 600w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/B50-2-768x691.png 768w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/B50-2-542x489.png 542w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/B50-2.png 870w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><figcaption id=\"caption-attachment-6868\" class=\"wp-caption-text\">Figur 1 &#8211; Exempelresultat fr\u00e5n ett LM-80-test. Notera medelv\u00e4rdespo\u00e4ngen vid varje tidpunkt f\u00f6r detta urval av LED-chips<\/figcaption><\/figure>\n<p>Tabellen ovan (Figur 1) visar ett exempel p\u00e5 hur LM-80-resultaten samlas in och vilka resultat som anv\u00e4nds i TM-21-ber\u00e4kningen.<\/p>\n<p>Resultatet av ovanst\u00e5ende \u00e4r klassad underh\u00e5llslivsl\u00e4ngd f\u00f6r ljusfl\u00f6det L<sub>x<\/sub>, vilket \u00e4r den f\u00f6rflutna drifttiden under vilken LED-ljusk\u00e4llan bibeh\u00e5ller procentandelen, <em>x<\/em>, av sin ursprungliga ljusutstr\u00f6m. Till exempel: <em>L<sub>70<\/sub> (timmar) = tid tills 70 % ljusfl\u00f6desunderh\u00e5ll.<\/em><\/p>\n<p>Eftersom TM-21 definierar en ber\u00e4kning baserad p\u00e5 det genomsnittliga ljusfl\u00f6desunderh\u00e5llet vid varje m\u00e4tpunkt \u00e4r resultatet, per definition, <strong>genomsnittligt<\/strong> ljusfl\u00f6desunderh\u00e5ll f\u00f6r ett urval enheter efter den klassade underh\u00e5llslivsl\u00e4ngden. Med andra ord, efter de angivna timmarna kommer det aritmetiska medelv\u00e4rdet av urvalets ljusfl\u00f6desunderh\u00e5ll att vara L<sub>x<\/sub>-v\u00e4rdet. Eftersom ljusfl\u00f6desunderh\u00e5ll ungef\u00e4r f\u00f6ljer en normalf\u00f6rdelning kan vi ocks\u00e5 s\u00e4ga att f\u00f6r ett urval LED:ar f\u00f6rv\u00e4ntas h\u00e4lften av enheterna uppvisa ett h\u00f6gre ljusfl\u00f6desunderh\u00e5ll \u00e4n f\u00f6rv\u00e4ntat, och h\u00e4lften ett l\u00e4gre (se Figur 3 nedan).<\/p>\n<p><span style=\"color: #00a5db;\">Vi ser h\u00e4rav att den vanliga metod som specificeras i gatubelysningsupphandlingar, TM-21, endast kan projicera <em>genomsnittliga<\/em> ljusfl\u00f6desunderh\u00e5llsv\u00e4rden (f\u00f6r en normalf\u00f6rdelning \u00e4r medelv\u00e4rde = median = typv\u00e4rde), och med L<sub>x<\/sub>B<sub>y<\/sub>-notationen skulle representera L<sub>x<\/sub>B50. <\/span><\/p>\n<h4>Vilken effekt har B-v\u00e4rdet?<\/h4>\n<h6><span style=\"color: #f29621;\">Belysningsniv\u00e5er och energianv\u00e4ndning <\/span><\/h6>\n<p>Vissa gatubelysningsupphandlingar efterfr\u00e5gar projektioner av &#8221;B&#8221;-v\u00e4rden som inte representerar det genomsnittliga underh\u00e5llsprestanda f\u00f6r ljusfl\u00f6det. Till exempel L<sub>x<\/sub>B10, det vill s\u00e4ga antalet drifttimmar tills h\u00f6gst 10 % av LED:arna ger mindre \u00e4n x % av den initiala ljusutstr\u00f6mmen.<\/p>\n<p>Figur 2 visar att f\u00f6r LED:ar vars degradation f\u00f6ljer en normalf\u00f6rdelning \u00e4r B10 det ljusfl\u00f6desunderh\u00e5llsv\u00e4rde f\u00f6r vilket 10 % faller under L<sub>x<\/sub>-m\u00e5let och 90 % faller \u00f6ver tr\u00f6skeln.<\/p>\n<figure id=\"attachment_6878\" aria-describedby=\"caption-attachment-6878\" style=\"width: 700px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/L70B50_B10.png\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-6878\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/L70B50_B10-300x169.png\" alt=\"LED lumen maintenance follows a normal distribution\" width=\"700\" height=\"394\" srcset=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/L70B50_B10-300x169.png 300w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/L70B50_B10-600x338.png 600w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/L70B50_B10-1024x576.png 1024w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/L70B50_B10-768x432.png 768w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/L70B50_B10.png 1152w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/a><figcaption id=\"caption-attachment-6878\" class=\"wp-caption-text\">Figur 2 &#8211; LED-ljusfl\u00f6desunderh\u00e5ll f\u00f6ljer en normalf\u00f6rdelning<\/figcaption><\/figure>\n<p>F\u00f6r en given LED kommer antalet timmar f\u00f6r ett l\u00e4gre B<sub>y<\/sub>-v\u00e4rde alltid att vara f\u00e4rre \u00e4n antalet timmar till B50. Skillnaden beror p\u00e5 variationen i ljusfl\u00f6desunderh\u00e5ll uppm\u00e4tt mellan testprover. Ett B10-v\u00e4rde \u00e4r d\u00e4rf\u00f6r mer konservativt \u00e4n B50. I praktiken inneb\u00e4r detta att B10 n\u00e5s i ett tidigare skede i livsl\u00e4ngden f\u00f6r en upps\u00e4ttning LED-moduler j\u00e4mf\u00f6rt med B50.<\/p>\n<p>Som ett exempel: f\u00f6r en LED med L80B50 p\u00e5 100 000 timmar kan vi f\u00f6rv\u00e4nta oss att L80B10-v\u00e4rdet \u00e4r i storleksordningen 70 000 timmar. Vid denna tidpunkt kan vi s\u00e4ga att 10 % av LED:arna har mindre \u00e4n 80 % av ljusutstr\u00f6mmen. Som framg\u00e5r av Figur 3 \u00e4r dock den genomsnittliga ljusutstr\u00f6mmen f\u00f6r detta exempel efter 70 000 timmar faktiskt 87,5 %.<\/p>\n<p>Om en LED-gatubelysningsinstallation projekteras med en projektlivsl\u00e4ngd p\u00e5 70 000 timmar \u00e4r fr\u00e5gan f\u00f6r projekt\u00f6ren om man ska anv\u00e4nda L80B10 = 70 000 timmar och s\u00e4tta underh\u00e5llsfaktorn till 0,8, eller anv\u00e4nda L87,5B50 = 70 000 timmar och s\u00e4tta underh\u00e5llsfaktorn till 0,875. Det senare resulterar tydligtvis i <em>l\u00e4gre energif\u00f6rbrukning<\/em>.<\/p>\n<p>Det kan h\u00e4vdas att det genomsnittliga ljusfl\u00f6desunderh\u00e5llsv\u00e4rdet \u00e4r mer l\u00e4mpligt vid val av underh\u00e5llsfaktor, eftersom vi vill s\u00e4kerst\u00e4lla att projektet varken \u00e4r underbelyst eller \u00f6verbelyst. Med exemplet ovan, om L80B10 anv\u00e4nds, kommer projektet att vara \u00f6verbelyst med 7,5 % i genomsnitt, j\u00e4mf\u00f6rt med L87,5B50 d\u00e4r det inte \u00e4r det (b\u00e5da \u00e4r 70 000 timmar).<\/p>\n<p><span style=\"color: #00a5db;\">Gl\u00f6m inte att en LED-armatur vanligtvis inneh\u00e5ller ett antal LED:ar. LED-chips degraderar i olika takt, varf\u00f6r ljusfl\u00f6desdegradationen f\u00f6r armaturen redan utg\u00f6r ett genomsnitt av de enskilda LED-chipsen i enheten.<\/span><\/p>\n<h6><span style=\"color: #f29621;\">Noggrannhet i armaturj\u00e4mf\u00f6relser<\/span><\/h6>\n<p><a href=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/comparing-apples-and-pears.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-6984 size-medium\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/comparing-apples-and-pears-300x201.jpg\" alt=\"\" width=\"300\" height=\"201\" srcset=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/comparing-apples-and-pears-300x201.jpg 300w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/comparing-apples-and-pears-600x401.jpg 600w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/comparing-apples-and-pears-768x514.jpg 768w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/comparing-apples-and-pears.jpg 1024w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>F\u00f6rutom risken f\u00f6r \u00f6verbelysning finns ett annat problem med anv\u00e4ndningen av &#8221;B&#8221;-v\u00e4rden, n\u00e4mligen hur de ber\u00e4knas. TM-21 \u00e4r en definierad ber\u00e4kningsmetod f\u00f6r genomsnittligt ljusfl\u00f6desunderh\u00e5ll och kr\u00e4ver att LED:arna testas enligt LM-80. TM-21 ger dock ingen v\u00e4gledning om hur &#8221;B&#8221;-v\u00e4rden ska ber\u00e4knas.<\/p>\n<p><span style=\"color: #00a5db;\">F\u00f6ljaktligen ber\u00e4knas alla uppgivna v\u00e4rden med en metod som v\u00e4ljs av tillverkaren. Detta \u00e4r problematiskt eftersom avsaknaden av ett standardiserat tillv\u00e4gag\u00e5ngss\u00e4tt inneb\u00e4r att resultaten inte kan j\u00e4mf\u00f6ras p\u00e5 ett likv\u00e4rdigt s\u00e4tt, vilket i b\u00e4sta fall g\u00f6r beslutsprocessen mellan armaturer sv\u00e5rare.<\/span><strong><br \/>\n<\/strong><\/p>\n<h6><span style=\"color: #f29621;\">Tolkning av brittiska standarder<\/span><\/h6>\n<p><a href=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/British-Standards.png\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-6986 alignnone\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/02\/British-Standards.png\" alt=\"\" width=\"258\" height=\"148\" \/><\/a><\/p>\n<p>Bilaga C till BS 5489-1 beskriver processen f\u00f6r ber\u00e4kning av underh\u00e5llsfaktorer f\u00f6r LED-gatubelysning att anv\u00e4ndas i belysningsprojektering.<\/p>\n<p><strong>Detta dokument h\u00e4nvisar endast till ljusfl\u00f6desunderh\u00e5ll som ett L<sub>x<\/sub>-v\u00e4rde <\/strong><em><strong>utan metod f\u00f6r att inkludera B<sub>y<\/sub>-v\u00e4rden i ekvationen<\/strong>. Det inneb\u00e4r att anv\u00e4ndning av n\u00e5got annat \u00e4n B50 kan anses vilseledande.<\/em><\/p>\n<h4>Att f\u00f6rst\u00e5 B<sub>Y<\/sub>-v\u00e4rden: Variation i ljusfl\u00f6desdegradation<\/h4>\n<p>En viktig faktor som &#8221;B&#8221;-v\u00e4rdet f\u00f6rs\u00f6ker belysa \u00e4r variationen i ljusfl\u00f6desunderh\u00e5ll mellan LED-prover under testning.<\/p>\n<p>Om vi till exempel har ett urval p\u00e5 10 LED:ar och driver dem i 100 000 timmar vore det mer \u00f6nskv\u00e4rt att de uppm\u00e4tta ljusfl\u00f6desunderh\u00e5llsresultaten liknar &#8221;Exempel 1&#8221; i Figur 3 nedan snarare \u00e4n &#8221;Exempel 2&#8221;.<\/p>\n<p><a href=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/Fig-4.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-6881\" src=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/Fig-4-300x118.jpg\" alt=\"Table showing variation in lumen maintenance factors for LED Street Lighting\" width=\"600\" height=\"236\" srcset=\"https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/Fig-4-300x118.jpg 300w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/Fig-4-600x235.jpg 600w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/Fig-4-768x301.jpg 768w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/Fig-4-960x379.jpg 960w, https:\/\/indolighting.com\/wp-content\/uploads\/2018\/01\/Fig-4.jpg 966w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/p>\n<p><em>Figur 3. Variation i ljusfl\u00f6desunderh\u00e5ll mellan prover <\/em><\/p>\n<p>Sk\u00e4let till detta \u00e4r att trots att de har samma genomsnittliga ljusfl\u00f6desdegradation (och d\u00e4rmed identiska L80B50-v\u00e4rden) erbjuder Exempel 1 st\u00f6rre konsekvens i ljusfl\u00f6desunderh\u00e5llet. Det inneb\u00e4r att alla LED:ar skulle degradera mycket j\u00e4mnare och d\u00e4rmed ge en mer konsistent ljusutstr\u00f6m \u00f6ver tid.<\/p>\n<p>Om vi kunde vara s\u00e4kra p\u00e5 att samma metoder anv\u00e4ndes f\u00f6r att ber\u00e4kna B10-v\u00e4rden f\u00f6r b\u00e5da exempelupps\u00e4ttningarna, skulle kvaliteten hos exempelupps\u00e4ttning 1 framh\u00e4vas av beg\u00e4ran om L80B10. I verkligheten finns det, som vi vet, ingen standardisering f\u00f6r ber\u00e4kningen av detta m\u00e4tv\u00e4rde, vilket inneb\u00e4r att j\u00e4mf\u00f6relser inte alltid \u00e4r meningsfulla.<\/p>\n<p>Ett alternativt s\u00e4tt f\u00f6r kunder att samla information om variabilitet \u00e4r att kontrollera variansen eller standardavvikelsen i resultaten fr\u00e5n en enhets LM-80-testrapport. Eftersom LM-80 \u00e4r ett branschstandardtestf\u00f6rfarande s\u00e4kerst\u00e4ller detta en r\u00e4ttvis och robust j\u00e4mf\u00f6relse mellan likv\u00e4rdiga armaturer.<\/p>\n<p>Detta kan till och med inkluderas i upphandlingsdokument genom att helt enkelt ange en maximal till\u00e5ten standardavvikelse (ett m\u00e5tt p\u00e5 variationen av resultat fr\u00e5n genomsnittet) f\u00f6r varje ljusfl\u00f6desunderh\u00e5llsm\u00e4tpunkt under LM-80-testprocessen.<\/p>\n<h4>Sammanfattning<\/h4>\n<p><strong>Anv\u00e4ndning av alternativa &#8221;B&#8221;-v\u00e4rden j\u00e4mf\u00f6rt med standard-TM-21-projektioner kan:<\/strong><\/p>\n<ul>\n<li><strong>Resultera i ett \u00f6verbelyst projekt och d\u00e4rmed h\u00f6gre livscykelkostnader<\/strong><\/li>\n<li><strong>G\u00f6ra bed\u00f6mningar mellan olika lykter sv\u00e5rare, eftersom det inte finns n\u00e5gon standard som s\u00e4kerst\u00e4ller att tillverkarna anv\u00e4nder samma ber\u00e4kning. TM-21 \u00e4r d\u00e4remot detsamma f\u00f6r alla tillverkare<\/strong><\/li>\n<\/ul>\n<p><span style=\"color: #00a5db;\"><strong>Att anv\u00e4nda B50 \u00e4r det mest tr\u00e4ffs\u00e4kra och l\u00e4mpliga m\u00e5ttet f\u00f6r att s\u00e4kerst\u00e4lla konsekvens med underh\u00e5llsfaktorer f\u00f6r LED-gatubelysningsprincipen och samtidigt maximera installationens livsl\u00e4ngd och effektivitet.<\/strong><\/span><\/p>\n<p>Det \u00e4r naturligtvis aldrig riktigt s\u00e5 enkelt som det l\u00e5ter.<\/p>\n<p>\u00c4ven om det finns tydliga f\u00f6rdelar med att anv\u00e4nda TM-21 och bortse fr\u00e5n alla &#8221;B&#8221;-p\u00e5st\u00e5enden, \u00e4r problemet med TM-21 att en LED med h\u00f6g grad av variation i ljusfl\u00f6desunderh\u00e5ll mellan LED-prover behandlas likadant som en LED med mycket konsekvent ljusfl\u00f6desunderh\u00e5ll mellan LED-prover.<\/p>\n<p><span style=\"color: #00a5db;\">Det \u00e4r d\u00e4rf\u00f6r \u00f6nskv\u00e4rt att specificera en LED-k\u00e4lla med s\u00e5 liten variation i ljusfl\u00f6desunderh\u00e5llsprestanda som m\u00f6jligt. Detta kan g\u00f6ras p\u00e5 ett konsekvent och j\u00e4mf\u00f6rbart s\u00e4tt genom att specificera minimalt observerade variationer i LM-80-testresultaten (se beigmarkerad standardavvikelserad i Figur 2).<\/span><\/p>\n<p>Att anv\u00e4nda mer energi \u00e4n vad som kr\u00e4vs f\u00f6r att uppfylla standarderna \u00e4r uppenbarligen inte \u00f6nskv\u00e4rt. Att s\u00e4tta ett m\u00e5lprestandam\u00e4tv\u00e4rde som L80B10 orsakar inte bara detta och \u00e4r \u00f6ppet f\u00f6r manipulation, utan p\u00e5verkar ocks\u00e5 m\u00f6jligheten att j\u00e4mf\u00f6ra armaturer p\u00e5 ett korrekt s\u00e4tt.<\/p>\n<p><em>Lawrence Baynham MEng \u00e4r teknisk direkt\u00f6r p\u00e5 INDO Lighting. Hans slutsatser publicerades i ILP Lighting Journal november\/december 2017 under titeln &#8221;Diminishing Returns&#8221;, och presenterades i hans webbinarium &#8221;To B50 or not to B50&#8221;.<\/em><\/p>\n<p><a href=\"#_ftnref1\" name=\"_ftn1\">[1]<\/a> <a href=\"https:\/\/www.ies.org\/product\/projecting-long-term-lumen-maintenance-of-led-light-sources\/\" target=\"_blank\" rel=\"noopener noreferrer\">TM-21-11 Projecting Long-Term Lumen Maintenance of LED Light Sources &#8211; Illuminating Engineering Society of North America (IESNA)<\/a><\/p>\n<p><a href=\"#_ftnref2\" name=\"_ftn2\">[2]<\/a> <a href=\"https:\/\/www.ies.org\/product\/ies-nalmco-recommended-practice-for-lighting-maintenance\/\" target=\"_blank\" rel=\"noopener noreferrer\">LM-80-08 Approved Method: Measuring Lumen Maintenance of LED Light Sources &#8211; IESNA<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>N\u00e4r man v\u00e4ljer r\u00e4tt ljusfl\u00f6desm\u00e4ssiga underh\u00e5llsfaktorer f\u00f6r LED-gatubelysning \u00e4r det avg\u00f6rande att ta h\u00e4nsyn till r\u00e4tt m\u00e4ngd ljusfl\u00f6desdegradation f\u00f6r att s\u00e4kerst\u00e4lla att ett belysningsprojekt uppfyller kraven vid slutet av sin livsl\u00e4ngd. St\u00e4ller belysningsproffs r\u00e4tt fr\u00e5gor till sina leverant\u00f6rer? Det \u00e4r v\u00e4lk\u00e4nt att LED:ens ljusutstr\u00f6m minskar \u00f6ver tid, det som kallas ljusfl\u00f6desdegradation. F\u00f6r att s\u00e4kerst\u00e4lla att [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":7001,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[129],"tags":[131],"class_list":["post-20527","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-exterior-lighting"],"_links":{"self":[{"href":"https:\/\/indolighting.com\/sv\/wp-json\/wp\/v2\/posts\/20527","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/indolighting.com\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/indolighting.com\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/indolighting.com\/sv\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/indolighting.com\/sv\/wp-json\/wp\/v2\/comments?post=20527"}],"version-history":[{"count":1,"href":"https:\/\/indolighting.com\/sv\/wp-json\/wp\/v2\/posts\/20527\/revisions"}],"predecessor-version":[{"id":20528,"href":"https:\/\/indolighting.com\/sv\/wp-json\/wp\/v2\/posts\/20527\/revisions\/20528"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/indolighting.com\/sv\/wp-json\/wp\/v2\/media\/7001"}],"wp:attachment":[{"href":"https:\/\/indolighting.com\/sv\/wp-json\/wp\/v2\/media?parent=20527"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/indolighting.com\/sv\/wp-json\/wp\/v2\/categories?post=20527"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/indolighting.com\/sv\/wp-json\/wp\/v2\/tags?post=20527"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}